1.
EJNMMI Res ; 12(1): 49, 2022 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-35962869

RESUMO

The experimental outcomes of small-animal positron emission tomography (PET) imaging with 18F-labelled fluorodeoxyglucose (18F-FDG) can be particularly compromised by animal preparation and care. Several works intend to improve research reporting and amplify the quality and reliability of published research. Though these works provide valuable information to plan and conduct animal studies, manuscripts describe different methodologies-standardization does not exist. Consequently, the variation in details reported can explain the difference in the experimental results found in the literature. Additionally, the resources and guidelines defining protocols for small-animal imaging are scarce, making it difficult for researchers to obtain and compare accurate and reproducible data. Considering the selection of suitable procedures key to ensure animal welfare and research improvement, this paper aims to prepare the way for a future guideline on mice preparation and care for PET imaging with 18F-FDG. For this purpose, a global standard protocol was created based on recommendations and good practices described in relevant literature.

2.
Front Physiol ; 13: 906110, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35846002

RESUMO

Lately, the use of zebrafish has gained increased interest in the scientific community as an animal model in preclinical research. However, there is a lack of in vivo imaging tools that ensure animal welfare during acquisition procedures. The use of functional imaging techniques, like Positron Emission Tomography (PET), in zebrafish is limited since it requires the animal to be alive, representing a higher instrumentation complexity when compared to morphological imaging systems. In the present work, a new zebrafish enclosure was developed to acquire in vivo images while monitoring the animal's welfare through its heartbeat. The temperature, dissolved oxygen, and pH range in a closed aquatic environment were tested to ensure that the conditions stay suitable for animal welfare during image acquisitions. The developed system, based on an enclosure with a bed and heartbeat sensors, was tested under controlled conditions in anesthetized fishes. Since the anesthetized zebrafish do not affect the water quality over time, there is no need to incorporate water circulation for the expected time of PET exams (about 30 min). The range of values obtained for the zebrafish heart rate was 88-127 bpm. The developed system has shown promising results regarding the zebrafish's heart rate while keeping the fish still during the long imaging exams. The zebrafish enclosure ensures the animal's well-being during the acquisition of in vivo images in different modalities (PET, Computer Tomography, Magnetic Resonance Imaging), contributing substantially to the preclinical research.

3.
Spectrochim Acta A Mol Biomol Spectrosc ; 172: 163-167, 2017 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-27133357

RESUMO

Rare earth orthosilicates are among the most widely used scintillator materials in the last decades. Particularly, lutetium-yttrium oxyorthosilicate (LYSO) is known to exhibit great potentialities in the field of radiation detectors for medical imaging. Consequently, an in-depth knowledge of the material properties is of utmost interest for the mentioned applications. In this work the spectroscopic properties of commercial cerium doped lutetium-yttrium oxyorthosilicate crystals (LYSO:Ce) were investigated by Raman spectroscopy, steady state photoluminescence, photoluminescence excitation and time resolved photoluminescence. Site selective excitation was used under steady state (325nm) and pulsed (266nm) conditions to separately investigate the temperature dependence of the 5d→4f Ce1 and Ce2 luminescence, allowing to establish the thermal quenching dependence of the Ce2 optical center. In the case of the Ce1 optical center, a luminescence quantum efficiency of 78% was obtained from 14K to room temperature with 266nm photon excitation.

4.
Philos Trans A Math Phys Eng Sci ; 369(1953): 4064-77, 2011 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-21930565

RESUMO

It is now recognized that the International System of Units (SI units) will be redefined in terms of fundamental constants, even if the date when this will occur is still under debate. Actually, the best estimate of fundamental constant values is given by a least-squares adjustment, carried out under the auspices of the Committee on Data for Science and Technology (CODATA) Task Group on Fundamental Constants. This adjustment provides a significant measure of the correctness and overall consistency of the basic theories and experimental methods of physics using the values of the constants obtained from widely differing experiments. The physical theories that underlie this adjustment are assumed to be valid, such as quantum electrodynamics (QED). Testing QED, one of the most precise theories is the aim of many accurate experiments. The calculations and the corresponding experiments can be carried out either on a boundless system, such as the electron magnetic moment anomaly, or on a bound system, such as atomic hydrogen. The value of fundamental constants can be deduced from the comparison of theory and experiment. For example, using QED calculations, the value of the fine structure constant given by the CODATA is mainly inferred from the measurement of the electron magnetic moment anomaly carried out by Gabrielse's group. (Hanneke et al. 2008 Phys. Rev. Lett. 100, 120801) The value of the Rydberg constant is known from two-photon spectroscopy of hydrogen combined with accurate theoretical quantities. The Rydberg constant, determined by the comparison of theory and experiment using atomic hydrogen, is known with a relative uncertainty of 6.6×10(-12). It is one of the most accurate fundamental constants to date. A careful analysis shows that knowledge of the electrical size of the proton is nowadays a limitation in this comparison. The aim of muonic hydrogen spectroscopy was to obtain an accurate value of the proton charge radius. However, the value deduced from this experiment contradicts other less accurate determinations. This problem is known as the proton radius puzzle. This new determination of the proton radius may affect the value of the Rydberg constant . This constant is related to many fundamental constants; in particular, links the two possible ways proposed for the redefinition of the kilogram, the Avogadro constant N(A) and the Planck constant h. However, the current relative uncertainty on the experimental determinations of N(A) or h is three orders of magnitude larger than the 'possible' shift of the Rydberg constant, which may be shown by the new value of the size of the proton radius determined from muonic hydrogen. The proton radius puzzle will not interfere in the redefinition of the kilogram. After a short introduction to the properties of the proton, we will describe the muonic hydrogen experiment. There is intense theoretical activity as a result of our observation. A brief summary of possible theoretical explanations at the date of writing of the paper will be given. The contribution of the proton radius puzzle to the redefinition of SI-based units will then be examined.

5.
Phys Rev Lett ; 104(14): 142503, 2010 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-20481936

RESUMO

An unusual but effective way to determine at threshold the dpi<-->NN transition strength alpha is to exploit the hadronic ground-state broadening Gamma(1s) in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi(-)-->nn, which is related to s-wave pion production pp-->dpi(+) by charge symmetry and detailed balance. Using the exotic atom circumvents the problem of Coulomb corrections to the cross section as necessary in the production experiments. Our dedicated measurement finds Gamma(1s)=(1171(-49)(+23)) meV yielding alpha=(252(-11)(+5)) microb.

6.
Anal Bioanal Chem ; 395(7): 2073-80, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19830408

RESUMO

A new system for energy-resolved X-ray fluorescence imaging using a microhole and strip plate (MHSP), a new type of micropattern gas detector (MPGD), is proposed. It works as a single photon counting detector with position and energy detection capability. The interaction of X-rays with the gas medium produces electrons via the photoelectric effect, and the number of electrons is proportional to the absorbed X-ray energy. These electrons are further multiplied in the MHSP. Position detection is achieved using the charge division method. The detector has an active area of 28 x 28 mm(2) and shows good position resolution, about sigma = 125 microm, an intrinsic energy resolution of about 14% FWHM for 5.9 keV X-rays, and a counting rate capability of up to 0.5 MHz. The system has shown good properties for energy-dispersive X-ray fluorescence (EDXRF) applications, since it allows efficient energy and position detection of fluorescence X-rays from multielemental samples. In this work, the system was used to study lead depth distributions in eighteenth-century Portuguese faiences from the Santa Clara-a-Velha monastery. The fluorescence images were obtained by irradiating the samples, with a pinhole placed between the sample and the detector to focus the radiation into the detector. The results are presented here, including the elemental map distributions for different samples.

7.
Phys Rev Lett ; 102(2): 023401, 2009 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-19257271

RESUMO

The (3p-1s) x-ray transition to the muonic hydrogen ground state was measured with a high-resolution crystal spectrometer. A Doppler effect broadening of the x-ray line was established which could be attributed to different Coulomb deexcitation steps preceding the measured transition. The assumption of a statistical population of the hyperfine levels of the muonic hydrogen ground state was directly confirmed by the experiment, and measured values for the hyperfine splitting can be reported. The results allow a decisive test of advanced cascade model calculations and establish a method to extract fundamental strong-interaction parameters from pionic hydrogen experiments.